CLASS zcl_abapgit_code_inspector DEFINITION
|
|
PUBLIC
|
|
CREATE PROTECTED
|
|
GLOBAL FRIENDS zcl_abapgit_factory .
|
|
|
|
PUBLIC SECTION.
|
|
|
|
INTERFACES zif_abapgit_code_inspector .
|
|
|
|
METHODS constructor
|
|
IMPORTING
|
|
!iv_package TYPE devclass
|
|
RAISING
|
|
zcx_abapgit_exception .
|
|
CLASS-METHODS validate_check_variant
|
|
IMPORTING
|
|
!iv_check_variant_name TYPE sci_chkv
|
|
RAISING
|
|
zcx_abapgit_exception .
|
|
PROTECTED SECTION.
|
|
DATA mv_package TYPE devclass .
|
|
|
|
METHODS create_variant
|
|
IMPORTING
|
|
!iv_variant TYPE sci_chkv
|
|
RETURNING
|
|
VALUE(ro_variant) TYPE REF TO cl_ci_checkvariant
|
|
RAISING
|
|
zcx_abapgit_exception .
|
|
METHODS cleanup
|
|
IMPORTING
|
|
!io_set TYPE REF TO cl_ci_objectset
|
|
RAISING
|
|
zcx_abapgit_exception .
|
|
METHODS skip_object
|
|
IMPORTING
|
|
!is_obj TYPE scir_objs
|
|
RETURNING
|
|
VALUE(rv_skip) TYPE abap_bool.
|
|
PRIVATE SECTION.
|
|
|
|
DATA mv_success TYPE abap_bool .
|
|
|
|
TYPES: ty_run_mode TYPE c LENGTH 1.
|
|
CONSTANTS:
|
|
BEGIN OF co_run_mode,
|
|
run_with_popup TYPE ty_run_mode VALUE 'P',
|
|
run_after_popup TYPE ty_run_mode VALUE 'A',
|
|
run_via_rfc TYPE ty_run_mode VALUE 'R',
|
|
run_in_batch TYPE ty_run_mode VALUE 'B',
|
|
run_loc_parallel TYPE ty_run_mode VALUE 'L',
|
|
run_direct TYPE ty_run_mode VALUE 'L',
|
|
END OF co_run_mode .
|
|
DATA mo_inspection TYPE REF TO cl_ci_inspection .
|
|
DATA mv_name TYPE sci_objs .
|
|
DATA mv_run_mode TYPE c LENGTH 1 .
|
|
|
|
|
|
METHODS create_objectset
|
|
RETURNING
|
|
VALUE(ro_set) TYPE REF TO cl_ci_objectset .
|
|
METHODS run_inspection
|
|
IMPORTING
|
|
!io_inspection TYPE REF TO cl_ci_inspection
|
|
RETURNING
|
|
VALUE(rt_list) TYPE scit_alvlist
|
|
RAISING
|
|
zcx_abapgit_exception .
|
|
METHODS create_inspection
|
|
IMPORTING
|
|
io_set TYPE REF TO cl_ci_objectset
|
|
io_variant TYPE REF TO cl_ci_checkvariant
|
|
RETURNING
|
|
VALUE(ro_inspection) TYPE REF TO cl_ci_inspection
|
|
RAISING
|
|
zcx_abapgit_exception .
|
|
|
|
METHODS decide_run_mode
|
|
RETURNING
|
|
VALUE(rv_run_mode) TYPE ty_run_mode.
|
|
ENDCLASS.
|
|
|
|
|
|
|
|
CLASS ZCL_ABAPGIT_CODE_INSPECTOR IMPLEMENTATION.
|
|
|
|
|
|
METHOD cleanup.
|
|
|
|
IF mo_inspection IS BOUND.
|
|
|
|
mo_inspection->delete(
|
|
EXCEPTIONS
|
|
locked = 1
|
|
error_in_enqueue = 2
|
|
not_authorized = 3
|
|
exceptn_appl_exists = 4
|
|
OTHERS = 5 ).
|
|
|
|
IF sy-subrc <> 0.
|
|
zcx_abapgit_exception=>raise( |Couldn't delete inspection. Subrc = { sy-subrc }| ).
|
|
ENDIF.
|
|
|
|
ENDIF.
|
|
|
|
io_set->delete(
|
|
EXCEPTIONS
|
|
exists_in_insp = 1
|
|
locked = 2
|
|
error_in_enqueue = 3
|
|
not_authorized = 4
|
|
exists_in_objs = 5
|
|
OTHERS = 6 ).
|
|
|
|
IF sy-subrc <> 0.
|
|
zcx_abapgit_exception=>raise( |Couldn't delete objectset. Subrc = { sy-subrc }| ).
|
|
ENDIF.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD constructor.
|
|
|
|
IF iv_package IS INITIAL.
|
|
zcx_abapgit_exception=>raise( |Please supply package| ).
|
|
ENDIF.
|
|
|
|
mv_package = iv_package.
|
|
|
|
" We create the inspection and objectset with dummy names.
|
|
" Because we want to persist them so we can run it in parallel.
|
|
" Both are deleted afterwards.
|
|
mv_name = |{ sy-uname }_{ sy-datum }_{ sy-uzeit }|.
|
|
mv_run_mode = decide_run_mode( ).
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD create_inspection.
|
|
|
|
cl_ci_inspection=>create(
|
|
EXPORTING
|
|
p_user = sy-uname
|
|
p_name = mv_name
|
|
RECEIVING
|
|
p_ref = ro_inspection
|
|
EXCEPTIONS
|
|
locked = 1
|
|
error_in_enqueue = 2
|
|
not_authorized = 3
|
|
OTHERS = 4 ).
|
|
|
|
IF sy-subrc <> 0.
|
|
zcx_abapgit_exception=>raise( |Failed to create inspection. Subrc = { sy-subrc }| ).
|
|
ENDIF.
|
|
|
|
ro_inspection->set(
|
|
p_chkv = io_variant
|
|
p_objs = io_set ).
|
|
|
|
ro_inspection->save(
|
|
EXCEPTIONS
|
|
missing_information = 1
|
|
insp_no_name = 2
|
|
not_enqueued = 3
|
|
OTHERS = 4 ).
|
|
|
|
IF sy-subrc <> 0.
|
|
zcx_abapgit_exception=>raise( |Failed to save inspection. Subrc = { sy-subrc }| ).
|
|
ENDIF.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD create_objectset.
|
|
|
|
DATA: lt_objs TYPE scit_objs,
|
|
ls_obj TYPE scir_objs,
|
|
lt_objs_check TYPE scit_objs,
|
|
ls_item TYPE zif_abapgit_definitions=>ty_item,
|
|
lt_packages TYPE zif_abapgit_sap_package=>ty_devclass_tt.
|
|
|
|
lt_packages = zcl_abapgit_factory=>get_sap_package( mv_package )->list_subpackages( ).
|
|
INSERT mv_package INTO TABLE lt_packages.
|
|
|
|
SELECT object AS objtype obj_name AS objname
|
|
FROM tadir
|
|
INTO CORRESPONDING FIELDS OF TABLE lt_objs
|
|
FOR ALL ENTRIES IN lt_packages
|
|
WHERE devclass = lt_packages-table_line
|
|
AND delflag = abap_false
|
|
AND pgmid = 'R3TR' ##TOO_MANY_ITAB_FIELDS. "#EC CI_GENBUFF
|
|
|
|
LOOP AT lt_objs INTO ls_obj.
|
|
|
|
IF skip_object( ls_obj ) = abap_true.
|
|
CONTINUE.
|
|
ENDIF.
|
|
|
|
ls_item-obj_type = ls_obj-objtype.
|
|
ls_item-obj_name = ls_obj-objname.
|
|
|
|
IF zcl_abapgit_objects=>exists( ls_item ) = abap_false.
|
|
CONTINUE.
|
|
ENDIF.
|
|
|
|
INSERT ls_obj INTO TABLE lt_objs_check.
|
|
|
|
ENDLOOP.
|
|
|
|
ro_set = cl_ci_objectset=>save_from_list(
|
|
p_name = mv_name
|
|
p_objects = lt_objs_check ).
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD create_variant.
|
|
|
|
IF iv_variant IS INITIAL.
|
|
zcx_abapgit_exception=>raise( |No check variant supplied.| ).
|
|
ENDIF.
|
|
|
|
cl_ci_checkvariant=>get_ref(
|
|
EXPORTING
|
|
p_user = ''
|
|
p_name = iv_variant
|
|
RECEIVING
|
|
p_ref = ro_variant
|
|
EXCEPTIONS
|
|
chkv_not_exists = 1
|
|
missing_parameter = 2
|
|
OTHERS = 3 ).
|
|
|
|
CASE sy-subrc.
|
|
WHEN 1.
|
|
zcx_abapgit_exception=>raise( |Check variant { iv_variant } doesn't exist| ).
|
|
WHEN 2.
|
|
zcx_abapgit_exception=>raise( |Parameter missing for check variant { iv_variant }| ).
|
|
ENDCASE.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD decide_run_mode.
|
|
|
|
DATA: lo_settings TYPE REF TO zcl_abapgit_settings.
|
|
lo_settings = zcl_abapgit_persist_settings=>get_instance( )->read( ).
|
|
|
|
IF sy-batch = abap_true.
|
|
" We have to disable parallelization in batch because of lock errors.
|
|
rv_run_mode = co_run_mode-run_via_rfc.
|
|
ELSEIF lo_settings->get_parallel_proc_disabled( ) = abap_false.
|
|
rv_run_mode = co_run_mode-run_loc_parallel.
|
|
ELSE.
|
|
rv_run_mode = co_run_mode-run_via_rfc.
|
|
ENDIF.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD run_inspection.
|
|
|
|
io_inspection->run(
|
|
EXPORTING
|
|
p_howtorun = mv_run_mode
|
|
EXCEPTIONS
|
|
invalid_check_version = 1
|
|
OTHERS = 2 ).
|
|
|
|
IF sy-subrc <> 0.
|
|
zcx_abapgit_exception=>raise( |Code inspector run failed. Subrc = { sy-subrc }| ).
|
|
ENDIF.
|
|
|
|
io_inspection->plain_list( IMPORTING p_list = rt_list ).
|
|
|
|
SORT rt_list BY objtype objname test code sobjtype sobjname line col.
|
|
|
|
DELETE ADJACENT DUPLICATES FROM rt_list.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD skip_object.
|
|
|
|
DATA: ls_trdir TYPE trdir.
|
|
|
|
CASE is_obj-objtype.
|
|
WHEN 'PROG'.
|
|
|
|
SELECT SINGLE *
|
|
INTO ls_trdir
|
|
FROM trdir
|
|
WHERE name = is_obj-objname.
|
|
|
|
rv_skip = boolc( ls_trdir-subc = 'I' ). " Include program.
|
|
|
|
WHEN OTHERS.
|
|
rv_skip = abap_false.
|
|
|
|
ENDCASE.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD validate_check_variant.
|
|
|
|
cl_ci_checkvariant=>get_ref(
|
|
EXPORTING
|
|
p_user = ''
|
|
p_name = iv_check_variant_name
|
|
EXCEPTIONS
|
|
chkv_not_exists = 1
|
|
missing_parameter = 2
|
|
OTHERS = 3 ).
|
|
|
|
IF sy-subrc <> 0.
|
|
zcx_abapgit_exception=>raise( |No valid check variant { iv_check_variant_name }| ).
|
|
ENDIF.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD zif_abapgit_code_inspector~is_successful.
|
|
|
|
rv_success = mv_success.
|
|
|
|
ENDMETHOD.
|
|
|
|
|
|
METHOD zif_abapgit_code_inspector~run.
|
|
|
|
DATA: lo_set TYPE REF TO cl_ci_objectset,
|
|
lo_variant TYPE REF TO cl_ci_checkvariant,
|
|
lx_error TYPE REF TO zcx_abapgit_exception.
|
|
|
|
|
|
TRY.
|
|
lo_set = create_objectset( ).
|
|
|
|
IF lines( lo_set->iobjlst-objects ) = 0.
|
|
" no objects, nothing to check
|
|
RETURN.
|
|
ENDIF.
|
|
|
|
lo_variant = create_variant( iv_variant ).
|
|
|
|
mo_inspection = create_inspection(
|
|
io_set = lo_set
|
|
io_variant = lo_variant ).
|
|
|
|
rt_list = run_inspection( mo_inspection ).
|
|
|
|
cleanup( lo_set ).
|
|
|
|
IF iv_save = abap_true.
|
|
READ TABLE rt_list TRANSPORTING NO FIELDS WITH KEY kind = 'E'.
|
|
mv_success = boolc( sy-subrc <> 0 ).
|
|
ENDIF.
|
|
|
|
CATCH zcx_abapgit_exception INTO lx_error.
|
|
|
|
" ensure cleanup
|
|
cleanup( lo_set ).
|
|
zcx_abapgit_exception=>raise( iv_text = lx_error->get_text( )
|
|
ix_previous = lx_error ).
|
|
|
|
ENDTRY.
|
|
|
|
ENDMETHOD.
|
|